The U.S. Coast Guard Academy requires a qualified, licensed electrical contractor to inspect, repair as necessary, test, and restore Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear, with primary work focused on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor shall inspect Cabinet 5 for damage or missing/cannibalized components; remove and replace three Eaton 15CLE-250E fuses; procure and deliver three additional matching fuses for on-site spares; perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards; provide certified test and field-service reports; coordinate all required outages and lockout/tagout procedures with the Government; and safely re-energize the cabinet and feeder upon successful completion of repairs and testing. All work shall comply with applicable OSHA, NFPA 70E, federal, state, and local requirements, including proper licensed personnel, arc-flash personal protective equipment, site protection, cleanup, and disposal of waste materials.
HOMELAND SECURITY, DEPARTMENT OF › US COAST GUARD › USCG ACADEMY
Inspect and Repair of 13.2KV Main Switchgear
Key facts
- Response deadline
- Nov 12, 2026
- 8:00 AM UTC-05:00
- Set-aside
- SBASmall business (total)
- Small Business Set Aside - Total
- Notice type
- Combined synopsis/solicitation
- Posted on SAM.gov
- Oct 30, 2026
- Archives Nov 27, 2026
Description
Contacts
Jerome Manuel · primary
CDR Avery Weston · secondary
(787) 729-2339
Attachments
BidLookup records the links this notice gives. It has not downloaded or checked the files.
Record dates
- Posted on SAM.gov: Oct 30, 2026
- The agency’s publication date, as SAM.gov states it.
- First recorded by BidLookup: Oct 30, 2026
- The UTC day of the first read of SAM.gov’s listings that stored this notice.
- Last confirmed: Nov 5, 2026
- The UTC day of the latest read that still listed this notice. It does not mean the notice is unchanged or still open on SAM.gov now, and it is not the index’s last-read time.
Published by the agency on SAM.gov as notice fe4d282a81414b2ba27f32e30140b0fa. What these dates mean
Record
- Solicitation number
- 70ZH1526QCGA00009
- Search the index for this number
- NAICS
- 238210 · Electrical Contractors and Other Wiring Installation Contractors
- Product/service code
- J061 · MAINT/REPAIR/REBUILD OF EQUIPMENT- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT
- Place of performance
- New London, Connecticut 06320
- Contracting office
- New London, CT 06320
- SAM.gov notice ID