Z2NE--FY26 INSPECTION OF WATER TANK SERVICES (B+OPT4)
Key facts
- Response deadline
- Nov 23, 2026
- 12:00 PM UTC-05:00
- Set-aside
- SDVOSBCService-disabled veteran-owned
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Notice type
- Combined synopsis/solicitation
- Posted on SAM.gov
- Nov 20, 2026
- Archives Feb 21, 2027
Description
Show the full descriptionShow less
Combined Synopsis-Solicitation for Commercial Products and Commercial Services Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01 (eff. 03/13/2026). This solicitation is set-aside for Service Disable Veteran Owned Small Business. The associated North American Industrial Classification System (NAICS) code for this procurement is 561210 Facilities Support services, with a small business size standard of 47.0 Size Standards in Millions of dollars. FSC/PSC is Z2NE Repair or Alteration of Water Supply Facilities. The Stratton VA Medical Center located at 113 Holland Ave, Albany, NY 12208 is seeking purchase inspection and cleaning services for Tank Lining of 14th-floor Water Tanks. All interested companies shall provide quotations for the following: Supplies/Services BASE:End of the preview. Use “Show the full description” above to read all of it.
Combined Synopsis-Solicitation for Commercial Products and Commercial Services
Description
This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.
This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01 (eff. 03/13/2026).
This solicitation is set-aside for Service Disable Veteran Owned Small Business.
The associated North American Industrial Classification System (NAICS) code for this procurement is 561210 Facilities Support services, with a small business size standard of 47.0 Size Standards in Millions of dollars.
FSC/PSC is Z2NE Repair or Alteration of Water Supply Facilities.
The Stratton VA Medical Center located at 113 Holland Ave, Albany, NY 12208 is seeking purchase inspection and cleaning services for Tank Lining of 14th-floor Water Tanks.
All interested companies shall provide quotations for the following:
Supplies/Services
BASE: 12/15/2026 11/30/2027
CLIN
Description of Goods or Service
Quantity
Units
Estimated Unit Price
TOTAL
0001
Inspect and clean two pressurized potable-water tanks, including file review, external/internal visual inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report.
1
JB
0002
Tank No. 1 surface preparation, lining, testing, disinfection, and return-to-service documentation.
1
JB
0003
Tank No. 2 surface preparation, lining, testing, disinfection, and return-to-service documentation.
1
JB
BASE YEAR TOTAL: $
Option Year 1: 12/01/2027 11/30/2028
1001
Inspect and clean two pressurized potable-water tanks, including file review, external/internal visual inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report.inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report.
1
JB
1002
Tank No. 1 surface preparation, lining, testing, disinfection, and return-to-service documentation.
1
JB
1003
Tank No. 2 surface preparation, lining, testing, disinfection, and return-to-service documentation.
1
JB
OPTION YEAR 1: $
Option Year 2: 12/01/2028 11/30/2029
2001
Inspect and clean two pressurized potable-water tanks, including file review, external/internal visual inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report.
1
JB
2002
Tank No. 1 surface preparation, lining, testing, disinfection, and return-to-service documentation.
1
JB
2003
Tank No. 2 surface preparation, lining, testing, disinfection, and return-to-service documentation.
1
JB
OPTION YEAR 2: $
Option Year 3: 12/01/2029 11/30/2030
3001
Inspect and clean two pressurized potable-water tanks, including file review, external/internal visual inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report.
1
JB
3002
Tank No. 1 surface preparation, lining, testing, disinfection, and return-to-service documentation.
1
JB
3003
Tank No. 2 surface preparation, lining, testing, disinfection, and return-to-service documentation.
1
JB
OPTION YEAR 3:$
Option Year 4: 12/01/2030 11/30/2031
4001
Inspect and clean two pressurized potable-water tanks, including file review, external/internal visual inspection, UTT, liner testing, confined-space entry/rescue, cleaning, and final report.
1
JB
4002
Tank No. 1 surface preparation, lining, testing, disinfection, and return-to-service documentation.
1
JB
4003
Tank No. 2 surface preparation, lining, testing, disinfection, and return-to-service documentation.
1
JB
OPTION YEAR 4: $
COMPLETE TOTAL: $
STATEMENT OF WORK
Inspection/Cleaning and Tank Lining of 14th-floor Water Tanks
Stratton VAMC, Albany, NY
Introduction Stratton VAMC s mission is to provide world-class healthcare for veterans in the capital region and upstate New York.
Background /Objective The Stratton VA Medical Center in Albany, New York, is currently seeking a vendor for the inspection and cleaning of two 25,000-gallon domestic cold water storage tanks located on the 14th floor of the Medical Center. These tanks supply the Medical Center's high loop, floors 5 through 14, with potable domestic water. These tanks also provide redundancy for the fire protection system throughout the building. It is the intent of this contract that the U-1 form (Manufacturer's Data Report for Pressure Vessels) be completed and submitted as required by the provisions of the ASME Boiler and Pressure Vessel Code Rules, Section VII, Division 1
Place of Performance Stratton VAMC, Albany, NY; Bldg. 1, 14th floor.
Period of Performance Work will take place Monday-Friday. 7 AM to 4 PM
Scope of Work The water storage tanks were installed in 1951 and cleaned/inspected in 2024. Tanks are sound and have not caused any issues, such as leaks or corrosion. They are housed inside on the 14th floor and set horizontally off the ground on a concrete cradle. The tanks are supplied with domestic water from the sub-basement via pumps that convey City of Albany municipal water from the street to the tanks. The tanks have a level float system for operational control. Additionally, the tanks are ASME-pressurized vessels, with compressed house air at the top of each tank, regulated to approximately 18 psi.
Specific Tasks cleaning and inspection-
Contractor will furnish all parts and labor to accomplish the task of File Review: Perform a review of the available equipment files reflecting original design, OEM construction drawings, repair documentation, and inspection records. The file review aims to fully assess the equipment's operational conditions and history.
Contractor will furnish all parts and labor to perform an external visual inspection (VT) utilizing trained engineering personnel competent in tank design and damage mechanisms. Inspections shall include, but are not limited to, the shell, welds, heads, nozzles, appurtenances, relief protection, foundation, and coatings.
Contractor will furnish all parts and labor to perform a Non-Destructive Testing inspection utilizing ultrasonic thickness testing (UTT) on the external shell as required. This work shall be performed by trained personnel meeting the requirements of the American Society of Non-Destructive Testing SNT-TC-1A.
Contractor will furnish all parts and labor to perform an internal (VT) inspection, liner thickness measurements, and spark testing of the glass liner, which shall be provided by a field service technician. Holiday testing will comply with Standard Practice for Discontinuity (Holiday) Testing of Nonconductive Protective Coating on Metallic Substrates, following ANSVAWWA D103-09 Section 12 by reference to the American Society for Testing and Materials (ASTM D1562-01) and STI SP001.
Contractor will furnish all parts and labor to ensure tanks are clean and free of any debris before putting tanks back in service.
Contractor will furnish all parts and labor to perform an evaluation, which includes an executive summary that outlines any conditions that inhibit the proper use and functionality of the equipment being inspected. And provides a comprehensive report with pictures and all documentation ascertained before, during, and after the inspections. The report should include, but not be limited to, the following:
UTT data and thickness measurement location (TML) map
Graphical representation of shell thickness data
Calculated minimum thickness
Wastage rates (if previous data is provided)
Remaining life expectancies (if previous data is provided)
Repair recommendations with criticality ranking
Inspection pictures
Future inspection intervals
Contractor will follow all OSHA confined space operating procedures, also having a confined space permit posted at the manway. The contractor will also provide a confined space rescue. Tanks should only be entered after air monitoring with a calibrated meter. Air monitoring must be continuous throughout the inspection.
Specific Tasks: Lining of the Tanks-
Contractor will furnish all parts and labor to accomplish the task of File Review: Perform a review of the available equipment files reflecting original design, OEM construction drawings, repair documentation, and inspection records. The file review aims to fully assess the equipment's operational conditions and history.
Contractor will furnish all parts and labor to perform an external visual inspection (VT) utilizing trained engineering personnel competent in tank design and damage mechanisms. Inspections shall include, but are not limited to, the shell, welds, heads, nozzles, appurtenances, relief protection, foundation, and coatings
Contractor will use NSF/ANSI 61 or 600 approved potable water-safe coatings or membranes, such as epoxy, polyurethane, or flexible PVC liners. Linings must be impermeable, corrosion-resistant, chemically resistant, and durable to protect steel or concrete substrates.
The contractor will follow all OSHA confined space operating procedures and will have a confined space permit posted at the manway. The contractor will also provide a confined space rescue. Tanks should only be entered after air monitoring with a calibrated meter. Air monitoring must be continuous throughout the inspection.
Interior of the tank to be blasted to a SP-10 (near white metal) to prepare for the tank lining
Tank to be coated with 25 35 mils of ACOR S-16 two-part epoxy
Delivery Schedule or Deliverables Contractor will deliver the finished report no later than 10 days after completion of testing. The report will be delivered to the COR.
Non-Compliance- The Contracting Officer or his/her designee will notify the Contractor of any noncompliance with the foregoing provisions and the action to be taken. The Contractor shall, after receipt of such notice, immediately correct the conditions to which attention has been directed. Such notice, when served on the Contractor or his/her representative at the site of the work, shall be deemed sufficient for the purpose aforesaid. If the Contractor fails or refuses to comply promptly, the Contracting Officer may issue an order stopping all and any part of the work and hold the Contractor in default.
Government Tasks-
VA personnel will empty tanks one at a time for inspection, cleaning, and lining.
VA personnel will deenergize pumps.
VA personnel will close all appropriate valves.
VA personnel will follow all steps to properly Lock Out/Tag Out (LOTO) all necessary valves, pumps, and equipment.
Inspection- Upon completion of the testing/cleaning service, the COR/POC will perform the inspection in the presence of the contractor personnel, prior to the contractor personnel leaving the facility. This inspection will ensure that all equipment is returned to full operational condition. No invoices will be processed for payment until the POC inspection is complete.
Other Related Services (Not Included in the Scope of Work)
Any services not expressly stated in this statement of work are not authorized. Services such as inspection, Original Equipment Manufacturer (OEM) required maintenance, or other maintenance and repair vital to the continued functioning of the systems may be added only after written modification from the contracting officer, unless they are included in the requested services. No person, including the COR or any other VA personnel, is authorized to request that the contractor perform additional work. Any additional services performed that are not authorized by the contracting officer will be considered inclusive.
The contract period of performance is:
Period of Performance: Base period and four option periods. Exact dates will be established at award. Work hours are Monday through Friday, 7:00 a.m. to 4:00 p.m., excluding Federal holidays, unless otherwise approved in writing.
Place of Performance: Stratton VA Medical Center, 113 Holland Avenue, Building 1, 14th Floor, Albany, New York 12208, United States.
Place of Performance/Place of Delivery
Address:
Stratton VAMC, Albany, NY; Bldg. 1, 14th floor.
Postal Code:
12208
Country:
UNITED STATES
The full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far.
The following solicitation provisions and clause apply to this acquisition:
FAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services
The electronic files should be in Portable Document Format (PDF) and named as follows: Vendor Name 36C24226Q0565 FY27- INSPECTION OF WATER TANK SERVICES If file size necessitates breaking a section into more than one file, please append File X of X to the end of the file name. All PDF files should be labeled to be considered responsive, the offeror must fill out all applicable areas of the solicitation, as well as any additional requirements/attachments listed below:
Part I Technical Capability (Factor 1) (2 copies)
Please see the evaluations, this is what you will be evaluated on.
Part II - Past Performance, (Factor 2) (2 copies)
Please see the evaluations, this is what you will be evaluated on.
Part III Pricing (Factor 3) (1 copies)
Completed and signed VAAR 852.219-75 certificate.
Active SAM registration and all required representations.
Completed pricing for every base and option CLIN.
The NCO2 Contracting Department requests two (2) Copies of your proposal: one unredacted and one redacted. The redacted copy must have all of your company s information redacted such as Company name, phone numbers, e-mail addresses and any information that can identify your company. When you provided any certifications please redact the person s name and company information as well. This does not apply to the attachments, but the 852.219-75 Limitations on Subcontracting - Compliance for Services and Construction must be completed by all vendors. Failure to follow this request will render your quote nonresponsive.
All quotes shall be sent to the Department of Veterans Affairs, Network Contracting Office (NCO) 2 via email to the Contract Officer Clifford S. Harrison at [email protected] by December 4th, 2026, at 12:00PM EST.
FAR 52.216-1 Type of Contract APR 1984 (DEVIATION NOV 2025)
FAR 52.219-1 Small Business Program Representations (FEB 2024) (DEVIATION NOV 2025)
FAR 52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998)
FAR 52.252-5 Authorized Deviations in Provisions (NOV 2020)
FAR 52.203-18 Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements or Statements-Representation (JAN 2017)
FAR 52.204-7 System for Award Management Registration NOV 2024 (DEVIATION NOV 2025)
852.215-72 Notice of Intent to Re-solicit (OCT 2019)
Award will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of RFO FAR 12.
FAR 52.212-2 Evaluation-Commercial Products and Commercial Services: In accordance with RFO FAR 12.201-1 and FAR 12.201-2 when appropriate, the contracting officer may (1) Insert the provision at 52.212-2, Evaluation-Commercial Products and Commercial Services, in solicitations for commercial products or commercial services.
The following are the decision factors:
The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered.
The following factors shall be used to evaluate offers;
Technical Capability
Technical Proficiency
Contractor Experience
Key Personnel
Certification
OSHA 10-Hour or
OSHA 30-Hour
Past Performance
Price
Evaluation Approach. The Government reserves the right to consider a quotation other than the lowest price that provides additional benefit(s). The Government reserves the right to select a quotation that provides benefit to the Government that exceeds the minimum requirements of the solicitation but is not required to do so. Each response must meet the minimum requirements of the solicitation. The Government is not requesting or accepting alternate quotations. Failure to provide the information requested may result in being found non-responsive. The evaluation will consider the following:
Evaluation factors. The Government will award a contract resulting from this solicitation to the Offeror responsible whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered.
For requests for proposals, state: Evaluation factors other
than price when combined are more important than price.
Technical Capability: Technical capability is defined as an offeror s ability to satisfy the solicitation s requirements, providing the highest quality service to the specified facilities. The Contractor shall provide a maximum 15-page capability statement demonstrating it has trained personnel, equipment, and working experience and ability to meet all the requirements of the Statement of Work (SOW).
TECHNICAL PROFICIENCY: The offer shall submit a proposal that verifies it is a firm that specializes in the INSPECTION OF WATER TANKS SERVICES. The proposal must be comprehensive and demonstrate an understanding of the requirements, not a copy-and-paste of the Statement of Work requirements. It shall outline the contractor s ability to perform the services adequately and satisfactorily in accordance with the Statement of Work (SOW) and the extent to which potential risks are identified and mitigated.
Contractor Experience: The offeror/prime vendor shall show three (3) instances under the prime vendor company of past-experience similar in nature, scope, complexity, difficulty, and size to that which will be supplied under the prospective contract contemplated by this solicitation. The experience shall reflect no less than three (3) years of service.
KEY PERSONNEL: The prime vendor shall identify key personnel and provide resumes for them. The contractor must specify whether subcontractors will be used; if so, provide the pertinent points of contact (POCs) for each subcontractor and describe their placement within the management hierarchy.
CERTIFICATION: The prime vendor must provide STI SP-001 AST inspector & API 510 pressure vessel inspector Certification to Qualify for This Requirement. An OSHA Certification will also need to be produced such as: OSHA 10-Hour or OSHA 30-Hour.
Past Performance: The prime contractor must provide three references under their company for a contract of similar scope and magnitude to be evaluated. Relevant past performance information shall include key personnel who have relevant experience, predecessor companies, and subcontractors who will perform major or critical elements of this solicitation. The contractors Past Performance shall also be reviewed in PPIRs; Individuals with no past performance shall receive a neutral rating for this evaluation factor.Â
Price: The government will evaluate offers for award purposes based on the pricing for the total requirement. Offers for partial requirements will not be evaluated and will be deemed non-responsive upon receipt.
(b) Options. The Government will evaluate offers for award purposes by adding the total price for all options to the total price for the basic requirement. The Government may determine that an offer is unacceptable if the option prices are significantly unbalanced. Evaluation of options shall not obligate the Government to exercise the option(s).
Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/.
FAR 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services (NOV 2023) (DEVIATION OCT 2025)
FAR 52.217-9 Option to Extend the Term of the Contract MAR 2000
FAR 52.222-90 Addressing DEI Discrimination by Federal Contractors APR 2026
FAR 52.240-91 Security Prohibitions and Exclusions (DEVIATION NOV 2025)
FAR 52.240-93 Basic Safeguarding of Covered Contractor Information Systems (DEVIATION NOV 2025)
VAAR 852.204-72 Personnel Vetting and Credentialing MAR 2026
852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction JAN 2023 OCT 2026 (DEVIATION)
52.252-2- Clauses Incorporated by Reference (FEB 1998)
52.203-17 Contractor Employee Whistleblower Rights (NOV 2023)
52.203-19 Prohibition on Required Certain Internal Confidentiality Agreements or Statements (JAN 2017)
52.204-9 Personal Identity Verification of Contractor Personnel (JAN 2011)
52.204-13 System for Award Management Maintenance OCT 2018 (DEVIATION NOV 2025)
52.209-6 Protecting the Government's Interest When Subcontracting With Contractors Debarred, Suspended, or Proposed for Debarment JAN 2025 (DEVIATION NOV 2025)
52.209-10 Prohibition on Contracting with Inverted Domestic Corporations NOV 2015 (DEVIATION NOV 2025)
52.217-8 Option to Extend Services (NOV 1999)
52.219-14 Limitations on Subcontracting OCT 2022 (DEVIATION NOV 2025)
52.219-28 Post award Small Business Program Representation JAN 2025 (DEVIATION NOV 2025)
52.222-3 Convict Labor (Deviation NOV 2025)
52.222-36 Equal Opportunity for Workers with Disabilities JUN 2020 (DEVIATION NOV 2025)
52.222-41 Service Contract Labor Standards AUG 2018 (DEVIATION NOV 2025)
52.222-42 Statement of Equivalent Rates for Federal Hires MAY 2014
52.222-50 Combating Trafficking in Persons NOV 2021 (DEVIATION OCT 2025)
52.222-54 Employment Eligibility Verification JAN 2025 (DEVIATION NOV 2025)
52.222-55 Minimum Wages for Contractor Workers Under Executive Order 14026 JAN 2022 (DEVIATION NOV 2025)
52.222-62 Paid Sick Leave Under Executive Order 13706 JAN 2022 (DEVIATION NOV 2025)
52.223-5 Pollution Prevention and Right-to-Know Information MAY 2014
52.226-8 Encouraging Contractor Policies to Ban Text Messaging While Driving MAY 2024
52.227-14 Rights in Data-General MAY 2014
52.232-33 Payment by Electronic Funds Transfer - System for Award Management OCT 2018
52.232-40 Providing Accelerated Payments to Small Business Subcontractors MAR 2023
52.233-4 Applicable Law for Breach of Contract Claim OCT 2004 (DEVIATION NOV 2025)
52.232-33 Payment by Electronic Funds Transfer-System for Award Management OCT 2018
52.232-40 Providing Accelerated Payments to Small Business Subcontractors MAR 2023
52.233-3 Protest after Award AUG 1996 (DEVIATION NOV 2025)
52.233-4 Applicable Law for Breach of Contract Claim OCT 2004 (DEVIATION NOV 2025)
52.237-2 Protection of Government, Buildings, Equipment and Vegetation APR 1984 DEVIATION NOV 2025
52.237-3 Continuity of Services JAN 1991
52.244-6 Subcontracts for Commercial Products and Commercial Services JAN 2025 (DEVIATION OCT 2025)
52.252-6 Authorized Deviations in Clauses NOV 2020
852.203-70 Commercial Advertising MAY 2018
852.204-70 Personal Identity Verification of Contractor Personnel MAY 2020 (DEVIATION FEB 2026)
852.232-72 Electronic Submission of Payment Requests NOV 2018
852.237-75 Key Personnel OCT 2019
To facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:
"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition."
Quoters shall list exception(s) and rationale for the exception(s), if any.
Submission of your response shall be received not later than December 4th, 2026, at 12:00PM EST at [email protected]. The email subject shall identify RFQ 36C24226Q0565. Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. All questions must be submitted no later than 12:00PM EST on November 30th, 2026. Answers to questions will be published via amendment to the solicitation.
Please note a site visit will be scheduled for November 25th, 2026, at 10AM Eastern Standard Time. All attendants will meet in the main lobby by the information desk.
Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(c) (3).
Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.
Point of Contact
Contracting Officer Clifford S. Harrison, [email protected]
See attached document: Stratton Wage Determination-SAM.gov.
See attached document: 852.219-75 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING
Contacts
Clifford S. Harrison · primary
718.584.9000 Ext.4680
Attachments
BidLookup records the links this notice gives. It has not downloaded or checked the files.
Record dates
- Posted on SAM.gov: Nov 20, 2026
- The agency’s publication date, as SAM.gov states it.
- First recorded by BidLookup: Nov 20, 2026
- The UTC day of the first read of SAM.gov’s listings that stored this notice.
- Last confirmed: Nov 20, 2026
- The UTC day of the latest read that still listed this notice. It does not mean the notice is unchanged or still open on SAM.gov now, and it is not the index’s last-read time.
Published by the agency on SAM.gov as notice c5eb2e53be0f45048000d3fa8da63b13. What these dates mean
Record
- Solicitation number
- 36C24226Q0565
- Search the index for this number
- NAICS
- 561210 · Facilities Support Services
- Product/service code
- Z2NE · REPAIR OR ALTERATION OF WATER SUPPLY FACILITIES
- Place of performance
- Albany, New York 12208
- Contracting office
- ALBANY, NY 12208
- SAM.gov notice ID
- c5eb2e53be0f45048000d3fa8da63b13