H144--Steam Quality Testing Service

Key facts

Response deadline
Nov 20, 2026
11:00 AM UTC-05:00
Set-aside
Not stated
Notice type
Solicitation
Posted on SAM.gov
Nov 13, 2026
Archives Dec 20, 2026

Description

Show the full description
Answers and Questions in response to solicitation 36C24627Q0084 Question 1) The price schedule lists 4 JB for CLIN 0001 and for each option year CLIN (1001 4001), while the CLIN descriptions and PWS describe an annual steam quality test and audit. How many testing events per year should be priced: one annual event, or four (quarterly)? Answer 1) The solicitation has since been updated. There was an error in the first posting. To clarify the testing needs to be done quarterly over a 12 month period (4 Quarterly testings). Question 2) If the quantity is 4 JB per year, does each JB represent a full test event (dryness, non-condensable gases and the steam, condensate and water audit), or a test at one location or sterilizer? Answer 2) Each JB represent a full test event for all Locations required. (3 each) Sterilizers and Associated Steam Traps. They also check the Condensate leaving the Sterilizers (Water Audit). Question 3) How many steam sample points are to be installed in the base year, and how many sterilizers or test points in Building 110A (CG48A) are to be tested at each event? Answer 3) There are three (3) Steam Sample Points, one on each Sterilizer. There is no need to install sample points during base year. The testing can be accomplished by removing a section of the steam piping to the Sterilizer, install testing equipment and complete testing.End of the preview. Use “Show the full description” above to read all of it.
Answers and Questions in response to solicitation 36C24627Q0084 Question 1) The price schedule lists 4 JB for CLIN 0001 and for each option year CLIN (1001 4001), while the CLIN descriptions and PWS describe an annual steam quality test and audit. How many testing events per year should be priced: one annual event, or four (quarterly)? Answer 1) The solicitation has since been updated. There was an error in the first posting. To clarify the testing needs to be done quarterly over a 12 month period (4 Quarterly testings). Question 2) If the quantity is 4 JB per year, does each JB represent a full test event (dryness, non-condensable gases and the steam, condensate and water audit), or a test at one location or sterilizer? Answer 2) Each JB represent a full test event for all Locations required.  (3 each) Sterilizers and Associated Steam Traps. They also check the Condensate leaving the Sterilizers (Water Audit). Question 3) How many steam sample points are to be installed in the base year, and how many sterilizers or test points in Building 110A (CG48A) are to be tested at each event? Answer 3) There are three (3) Steam Sample Points, one on each Sterilizer. There is no need to install sample points during base year. The testing can be accomplished by removing a section of the steam piping to the Sterilizer, install testing equipment and complete testing. Upon completion, remove testing equipment and return system to per-existing alignment of system.  However, if contract wants to for ease of access they can install points at their own expense. This is not a requirement of this Solicitation. Question 4) Please confirm whether we should price the broader audit scope for four jobs per year as listed in the price schedule, or the narrower testing scope once annually as stated in the Performance Work Statement. Answer 4) 4 jobs per year

Contacts

Attachments

BidLookup records the links this notice gives. It has not downloaded or checked the files.

Record dates

Posted on SAM.gov: Nov 13, 2026
The agency’s publication date, as SAM.gov states it.
First recorded by BidLookup: Nov 13, 2026
The UTC day of the first read of SAM.gov’s listings that stored this notice.
Last confirmed: Nov 13, 2026
The UTC day of the latest read that still listed this notice. It does not mean the notice is unchanged or still open on SAM.gov now, and it is not the index’s last-read time.

Published by the agency on SAM.gov as notice bcfaaf08f8e348f29a480a27dcb7e061. What these dates mean

Record

Solicitation number
36C24627Q0084
Search the index for this number
NAICS
561210 · Facilities Support Services
Product/service code
H144 · QUALITY CONTROL- FURNACE, STEAM PLANT, AND DRYING EQUIPMENT; NUCLEAR REACTORS