Skip to main content

← All opportunities

VETERANS AFFAIRS, DEPARTMENT OF › 250-NETWORK CONTRACT OFFICE 10 (36C250)

6515--Equipment - Ultrasounds - Ann Arbor

Key facts

Response deadline
Aug 5, 2026
12:00 PM UTC-04:00
Set-aside
Not stated
Notice type
Sources sought
Posted on SAM.gov
Jul 29, 2026
Archives Nov 12, 2026

Description

This is a SOURCES SOUGHT only pertaining to item(s) for the Ann Arbor VA healthcare facility. Information collected during this Sources Sought may be used in a set aside. If a solicitation is issued, the Government will do so in accordance with the Federal Acquisition Regulation (FAR) and applicable VA acquisition policies. The North American Industry Classification System (NAICS) number is 339112. The NAICS size is 1000 employees. Any contractor that believes they are capable and desires to claim preference for small business status must be registered with the Small Business Administration (SBA) and be able to be located through the SBA Dynamic Small Business Search. Any contractor that believes that they are capable and desires to claim preference for veteran-owned small business status must be registered in SBA at SBA.gov as a Service-Disabled Veteran-Owned Small Business (SDVOSB) or Veteran-Owned Small Business (VOSB). Contractors who deem themselves capable of meeting the requirement shall provide the information listed below to Kellie Konopinski, Contracting Officer at [email protected] no later than Wednesday, August 5, 2026, 12:00 p.m. EST., referencing Acquisition ID: 36C25026Q0807. Responses shall include: (1) Business Name and Address (2) Contract number items are covered under, if applicable (3) Point of Contact name, phone number, and email address (4) SAM UEI and NAICS code (5) Business size (Small or Large) (6) Type of business (SDVOSB, VOSB, 8(a), HUBZone, Woman-Owned, etc.) (7) Information about the
Show more
product proposed and identification of any salient characteristics not met (8) Country of manufacture (9) If the concern is not the manufacturer, provide the manufacturer s name, size standard, and an authorized distributor letter (10) If the concern is the manufacturer and sole distributor, provide documentation to that effect; if the manufacturer has authorized distributors, provide a list of those distributors (11) Contractor must confirm they can provide ALL required items. Contractors must be registered with https://www.sam.gov. To be considered SDVOSB/VOSB, contractors must be registered and certified in SBA. FOB is destination. Delivery is to: VA Ann Arbor Healthcare System 2215 Fuller Rd. Ann Arbor, MI 48105 Requirements: PICC Line placement vasculature positioning devices and accessories, brand name or equal to the following products: ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT 0001 SITERITE 9 KICKSTAND/MOUNTING KIT LOCAL STOCK NUMBER: 9770806 2.00 EA 0002 SITERITE 9 ULTRASOUND SYSTEM LOCAL STOCK NUMBER: 9770800 2.00 EA 0003 SITERITE 9 ULTRASOUND SYSTEM CUE LINEAR PROBE LOCAL STOCK NUMBER: 9770803 2.00 EA 0004 SHERLOCK 3CG TIP CONFIRMATION SENSOR LOCAL STOCK NUMBER: 9770358 2.00 EA 0005 MER2 ROLLSTAND LOCAL STOCK NUMBER: BAR000360 2.00 EA 0006 SONY MEDICAL PRINTER LOCAL STOCK NUMBER: UPX898MD 2.00 EA 0007 SONY PRINTER BRACK LOCAL STOCK NUMBER: BAR000206 2.00 EA Must meet the following requirements: 1. Integrated monitor and ultrasound machine (one machine for everything/vein access and PICC position) for vein assessment and access. Need a high clear resolution for needle tip tracking. 2. Integrated software program in the ultrasound machine that includes a remote control that has the software contained within the ultrasound probe itself. This helps ensure a sterile procedure field, with only one reach outside the field to grab the probe / remote. A separate remote requires a second reach and adds to expense with additional probe covers and replacements. 3. Disposable, individual ECG electrodes for each patient. (This reduces the potential for infectious pathogens to be spread from patient to patient, and room to room.) 4. A Sherlock T-piece tip tracker for the patient s chest, to visualize PICC tip entry into the subclavian, and allow for repositioning before procedure ends if needed. (This is useful for Afib and paced patients, who can t use ECG technology for PICC confirmation, but could still have a malpositioned PICC placement without this component) 5. ECG technology to confirm PICC Tip placement in the Superior Vena Cava all on one screen (No chest x-ray needed.) 6. Needle tip tracking technology to illuminate needle tip during vein cannulation and ensure pathway. 7. A true ambidextrous remote-control design.

From SAM.gov’s daily data file, as published on Oct 24, 2026 (UTC).

Contacts

Attachments

BidLookup records the links this notice gives. It has not downloaded or checked the files.

Record dates

Posted on SAM.gov: Jul 29, 2026
The agency’s publication date, as SAM.gov states it.
First recorded by BidLookup: Oct 8, 2026
The UTC day of the first read of SAM.gov’s listings that stored this notice.
Last confirmed: Oct 23, 2026
The UTC day of the latest read that still listed this notice. It does not mean the notice is unchanged or still open on SAM.gov now, and it is not the index’s last-read time.
Description as published: Oct 24, 2026 (UTC)
The date of the daily data file this text came from.

Published by the agency on SAM.gov as notice b154bc82ce9b4028aede5d3c3cdc5e70. What these dates mean

Record

Solicitation number
36C25026Q0807
Search the index for this number
NAICS
339112 · Surgical and Medical Instrument Manufacturing
Product/service code
6515 · MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
Place of performance
Ann Arbor, MI 48105
Contracting office
DAYTON, OH 45428
SAM.gov notice ID
b154bc82ce9b4028aede5d3c3cdc5e70