Skip to main content

← All opportunities

DEPT OF DEFENSE › DEPT OF THE ARMY › AMC › ACC › MISSION INSTALLATION CONTRACTING COMMAND › 419TH CSB › W6QM MICC-FT STEWART

Fire Extinguisher Service

Key facts

Response deadline
Sep 8, 2026
5:00 PM UTC-04:00
Set-aside
SBASmall business (total)
Small Business Set Aside - Total
Notice type
Presolicitation
Posted on SAM.gov
Sep 14, 2026
Archives Sep 23, 2026

Description

This is a non-personnel services contract to provide an initial assessment visit, pickup, inspections/maintenance, and delivery of 1239 fire extinguishers of various types and sizes pickup from various building locations on Hunter AAF. Each battalion within the brigade will schedule consolidated fire extinguisher services separately, on a quarterly basis, during this period. Contractor visits will occur at buildings 7901, 850, 860 and 1296 on HAAF. Services will be provided on a quarterly basis. Extinguisher Inventory 10LB: ABC 150 BC 28 Purple K 17 CO2 3 Halon 2 50LB: ABC 14 5LB: ABC 548 15LB: ABC 51 20LB: ABC 420 125LB: ABC 6 5. Specific Tasks: Tasks will be performed in accordance with NFPA 10, AR 420-5, and OSHA regulations. 5.1. The Contractor shall execute quarterly service dispatches to inspect and remediate 100% of inventory fire extinguishers, ensuring correction of all deficiencies within 5 business days. 5.2. The required fire extinguisher periodic maintenance includes annual inspections, 5/6 years maintenance (depending on the extinguisher type), and 10/12-year hydrostatic testing (depending on the extinguisher type). 5.3. Pressurized fire extinguishers require the following services (inspection, maintenance, and/or hydrostatic testing). 5.4. New extinguishers require an initial inspection to confirm the weight, pressure, condition, and provide the record on an inspection tag; all conducted by qualified personnel. 5.5.
Show more
Annual inspections/maintenance includes full mechanical check, weighing, and servicing by qualified personnel. 5.6. During 5/6 year maintenance, extinguishers must be disassembled, emptied, and serviced. 5.7. Hydrostatic testing involves the same process as 5/6 year maintenance with an addition structural test to ensure cylinder integrity. 5.8. 14 Days to perform service, unless an understanding is agreed upon between the unit POC, the contracting officer, and the contractor. In the event a unit is activated for deployment, the Government will not be responsible to pay for the quarterly services not used under the contract. The contractor will be notified by the COR, in writing, explaining the length of the deployment and the period during which services will not be required for a particular unit. The contractor will cease billing during the period during which services will not be required for a particular unit.

From SAM.gov’s daily data file, as published on Sep 23, 2026 (UTC). SAM.gov’s latest daily file no longer lists this notice.

Contacts

Attachments

BidLookup records the links this notice gives. It has not downloaded or checked the files.

Record dates

Posted on SAM.gov: Sep 14, 2026
The agency’s publication date, as SAM.gov states it.
First recorded by BidLookup: Sep 20, 2026
The UTC day of the first read of SAM.gov’s listings that stored this notice.
Last confirmed: Sep 20, 2026
The UTC day of the latest read that still listed this notice. It does not mean the notice is unchanged or still open on SAM.gov now, and it is not the index’s last-read time.
Description as published: Sep 23, 2026 (UTC)
The date of the daily data file this text came from.

Published by the agency on SAM.gov as notice 4aca7fc9fe274b41bdedba4e2f266011. What these dates mean

Record

Solicitation number
PANMCC-26-P-0000054269
Search the index for this number
NAICS
811310 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Product/service code
J012 · MAINT/REPAIR/REBUILD OF EQUIPMENT- FIRE CONTROL EQUIPMENT
Place of performance
Georgia 31409
Contracting office
FORT STEWART, GA 31314-3324
SAM.gov notice ID
4aca7fc9fe274b41bdedba4e2f266011